Glazing Risk Checklist

    Who This is For

    Strata Managers

    Building & Asset Managers

    Builders & Developers

    Facilities Managers

    If your building includes large-scale glazing, exposed corners or recurring condensation or leaks, this checklist is designed to support a structured review of system performance and condition.

    Have You Noticed Any of These?

    If any of the following look familiar in your building, the sections below can help you identify where the concern may originate.

    Glazing warning signs

    A Clearer Picture Starts Here.

    How To Use This Checklist

    Work through each section and consider whether the following items appear consistent with expected glazing performance and maintenance practices.

    YESappears consistent

    UNSUREmay require further review

    NOpotential concern identified

    0
    YES

    0
    UNSURE

    0
    NO

    41
    NOT YET SET

    1 Design and Compliance Considerations

    The glazing system appears to have been considered in relation to:

    AS 2047

    AS 1288

    NCC 2022 Amendment 2

    Documentation and engineering checks:

    Documentation is available relating to tested system performance

    Wind loads appear to have been determined using the appropriate standard (AS 4055 for housing, or AS/NZS 1170.2 for commercial or taller buildings)

    Design pressures appear generally consistent with the installed glazing system’s tested performance ratings

    Insight: Where documentation is unavailable or incomplete, it may be difficult to assess whether systems align with relevant performance expectations or compliance requirements.

    2 Installation and System Configuration

    The glazing system appears generally consistent with tested or specified configurations

    No obvious unauthorised modifications to framing, seals, or glass thickness are visible

    Mullion spans and fixings appear generally consistent with available specifications

    No apparent substitution of key glazing components or materials is evident

    Insight: Variations between installed systems and tested configurations may influence long-term system performance.

    3 Structural Performance Considerations

    Mullion deflection appears generally consistent with expected Serviceability Limit State (SLS) performance

    The glazing system appears to have been considered for Ultimate Limit State (ULS) wind loading conditions

    No visible indications of:

    Frame movement

    Bowing mullions

    Stress cracking

    Insight: Movement or deformation may contribute to water ingress or other longer-term performance concerns over time.

    4 Water Penetration and Sealing

    Documentation or evidence relating to water penetration resistance testing is available

    Seals appear intact, continuous and appropriately installed

    No visible indications of:

    Water staining around frames, sills, or surrounding walls and ceilings

    Surface deterioration: peeling, bubbling, or chipping paint or wallpaper

    Structural changes: swollen or warped frames, sagging plasterboard, loose tiles, or lifting floorboards

    Internal dampness, drafts, or localised temperature inconsistencies

    Condensation or fogging between glazing panes

    Mould or mildew near glazing systems

    Sealant deterioration or separation

    Difficulty operating windows or glazed doors

    Insight: Water ingress pathways are not always visible at the source and may originate from surrounding or concealed areas. Further investigation methods, such as AAMA 501.2 water testing, may assist in identifying potential water pathways where appropriate.

    5 Glass and Edge Support Conditions

    The glazing type appears generally suitable for its application in the context of AS 1288

    Glass edges appear adequately supported and protected

    No visible indications of:

    Edge chipping

    Stress fractures

    Incorrect glazing packers

    Edge delamination

    Glass deformation

    General glass defects

    Insight: Localised defects or inadequate edge support may affect glazing performance over time.

    6 Exposure and Higher-Risk Areas

    Corner glazing areas appear to have been considered in the overall design and installation

    High wind exposure areas appear to have been reviewed

    Large uninterrupted glazing panels appear to have been assessed in relation to their exposure conditions

    Higher-risk areas appear to have been engineered and reviewed following installation

    Insight: Corners, exposed elevations and large glazing panels are typically subject to increased wind and structural stresses, and may warrant closer review over time.

    7 Maintenance and Inspection Records

    A documented inspection or maintenance schedule is available

    Periodic inspections or facade reviews appear to have been undertaken

    Maintenance activities appear to be recorded and tracked

    Previously identified leaks or glazing concerns appear to have been investigated and addressed

    Insight: Ongoing inspection and maintenance records may assist in supporting long-term performance management and insurance-related processes.

    Your Details

    Performance Profile

    Mostly Yes: Conditions appear generally consistent with expected system performance, with ongoing monitoring recommended.

    Mix of Yes and Unsure: Some areas may benefit from further review or investigation.

    Multiple No: A more detailed assessment may assist in understanding potential performance concerns. Consider contacting a specialist for a structured assessment of your glazing system.

    Performance Depends on More Than Design

    Glazing systems are designed to perform under specific conditions. Where those conditions are not fully achieved through design, installation, environmental exposure, or ongoing maintenance, system performance may gradually change over time.

    Early identification through structured review may assist in addressing issues before they affect durability, performance, or broader building condition outcomes.

    Understanding Your Building’s Performance

    A structured assessment can help provide greater clarity on how glazing systems are performing and where additional attention may be beneficial.

    WS Remedial Group works with building owners and managers to support the long-term performance of glazing systems through:

    Facade and glazing inspections and reviews

    Compliance-focused assessments

    Leak diagnosis and investigation

    Targeted remedial works and maintenance support

    If you would like a clearer understanding of your building’s glazing condition and performance and learn more about specialist glazing led by people who've done this for decades, we are here to assist.

    Statement Of Responsibility

    This document is provided by WS Remedial Group as a general information guide only. It is not exhaustive and is not a substitute for project-specific professional advice. References to the NCC, Australian Standards, and industry practices are general in nature and should be verified against current official requirements.

    This document does not certify compliance or determine appropriate methods of assessment, design, repair, or rectification. Readers should obtain advice from appropriately qualified professionals, including registered practitioners where required, before relying on this information.

    To the maximum extent permitted by law, WS Remedial Group excludes liability for any loss arising from reliance on this document. Nothing in this statement excludes rights that cannot lawfully be excluded under the Australian Consumer Law.