Water Ingress and Rising Damp in a Concrete Slab: A Brisbane Case Study

Remedial waterproofing of annexe - Waterstop Solutions

Water Ingress and Rising Damp in a Concrete Slab: A Brisbane Case Study

A property owner in Brisbane contacted WS Remedial Group about water coming into an annexe on their property. What started as a leak at the base of the walls turned out to involve rising damp in the concrete slab as well. This case study shows how we found the cause and the steps we took to fix it.

The problem: water entering an annexe

The owner had noticed moisture coming in at floor level along the walls of the annexe. The floor was a concrete slab with a topping slab laid over it and a plastic membrane between the two.

What we found

Our inspector first planned to remove a strip of the topping slab and the plastic membrane along three of the four walls. This would give access to the floor-to-wall joints, so the team could seal them and then waterproof the wall and floor junction.

However, once the team lifted the first section, they found more than expected. Moisture was rising through the concrete slab underneath the topping slab. In addition, two concealed joints ran through the floor, and both showed signs of water getting in.

This is why investigation comes first. A fix aimed only at the wall joints would have left the rising damp and the floor joints untreated.

How we fixed it

To treat both the rising damp and the leaking joints, the team removed the topping slab across the floor. The work then followed five steps:

  1. Remove the topping slab to expose the concrete slab, the floor joints and the floor-to-wall joints.
  2. Inject the joints with a hydrophilic polyurethane resin, using high-pressure leak sealing injection. The resin reacts with water and fills the joint, sealing the path water was taking through the slab. We also injected leaks in the block wall.
  3. Prepare the surfaces by grinding the floor and walls smooth and vacuuming them clean.
  4. Install joint sealant along the floor-to-wall junction.
  5. Apply a reverse-side waterproofing system. We applied a water-borne epoxy (WBE) waterproofing system to the floor and turned it up onto the masonry walls, forming a new moisture barrier.

Protecting the new moisture barrier

UV light and wear from foot traffic or furniture can damage a WBE moisture barrier. For this reason, we recommend covering it with a floor finish such as tiles or carpet.

Remedial waterproofing of annexe works complete
10. WBE Waterproofing system installed to floor and walls. Remedial waterproofing works complete

 

Is rising damp in a concrete slab common?

It can happen in any on-ground slab where the moisture barrier underneath has failed or where joints and cracks give water a path. The signs are often hidden under floor coverings, so damp carpet, lifting tiles or a musty smell may be the first clue. Learn more about building moisture barrier solutions for walls and slabs, or read Damp patches on walls after rain: what could it be? to tell the different types of damp apart.

Talk to a specialist

WS Remedial Group diagnoses and repairs water ingress, rising damp and leaks in concrete structures across Queensland and New South Wales. This includes basements, balconies, slabs, lift pits, car parks and retaining walls. Learn more about our remedial waterproofing and rising damp treatment services.

Water coming through a slab or wall? Book an inspection or call 1800 005 000.